Key NB-50 Specifications
Available from stock and to order. The previously listed price for the basic version starts at 590 000 ₽; we will confirm the current price for the selected configuration in our quotation.
| Parameter | Value |
|---|---|
| Power | 50 kW |
| Piston Stroke | 160 mm |
| Double Stroke Rate | 105 per minute |
| Transmission Shaft Speed | 394 rpm |
| Connections: Suction / Discharge | 113 / 50 mm |
| Liner, mm | Flow Rate, l/s | Flow Rate, m³/h | Pressure, MPa |
|---|---|---|---|
| 90 | 5,8 | 20,9 | 6,3 |
| 100 | 7,3 | 26,3 | 5,0 |
| 110 | 8,9 | 32,0 | 4,1 |
| 120 | 11,0 | 39,6 | 3,4 |
The table shows operating conditions at 105 double strokes per minute. Operating values depend on the liner and fluid-end configuration. Maximum flow rate and pressure are not achieved simultaneously; the operating conditions of each pump are recorded in its technical data sheet.
Design Configuration
Configurations are available with the pulley on the right or left, with or without a clutch. When replacing a pump, the overall dimensions, mounting and drive side must be agreed along with the hydraulic specifications. The weight and dimensions of the selected configuration are stated in the specification.
Drive, Spare Parts and Maintenance
For a complete pumping unit, we agree the engine or motor, transmission, pulley side and base. For the initial operating period, we select liners, pistons, valves and seals according to the pump specification. Maintenance intervals, lubrication and tolerances are taken from the manual for the particular pump.
Manufacturing and Scope of Supply
We manufacture equipment to the agreed technical specification. Operating conditions, design and scope of supply are recorded before production starts. We confirm the completion date in our quotation. We arrange delivery across Russia and the CIS; transport, packaging and unloading are agreed with the equipment’s weight and dimensions in mind.
Your enquiry should specify the working fluid, the required flow rate and pressure together, drive type, operating conditions and delivery city. The scope of supply, documentation and spare parts are recorded in the specification.